The kitchen stove has no door. What can I buy to cover the bowl?

1. Woodworking \r\n 1, door frame and door cover: \r\nA. Make a horizontal line \r\nB. Punching holes with electric hammer shall not be less than 10mm, the depth shall not be less than 50mm, and the spacing shall not be greater than 350mm. \r\nC。 Nail them into your eyes with a dry wooden wedge. Nail the door frame with joinery board (the top plate is pressed on the two side plates), nail the bite (the specification is as per the design requirements), and install at least two layers of joinery board. \r\ne。 The door frame is embedded in the original door opening, and fixed horizontally and vertically on the wooden wedge with nails or wooden screws. The uneven part is made of wood board or plywood. \ r \ ngy powder should be vertical. \r\nF。 The door should be made of 9 cm board or 9 cm density board, and the core board should be made of plastic nails. (It's forbidden to use small wooden strips as doorways directly \ r \ n)\ r \ nG. The plywood or other decorative boards should be decorated. After the door is closed (according to the design requirements), the wooden line must be nailed with glue line. After closing, the wood line must be nailed firmly with glue and cannot be loosened. \r\n 2. Ceiling: \r\n A, pine or Chinese fir square (specification 3*5), planed on all sides, and coated with fire retardant paint. \r\n B, pay-off according to the design requirements. \r\n C, punch holes with electric hammer, not less than 60. N D, nail it into the eye with a dry wooden wedge (with building glue on it), and plane it with a plane above the wall. \r\n E, nail the frame according to the design requirements and do the modeling. The grid spacing of the frame is not more than 40mm. \r\n F, fix the frame with wooden suspenders, and the spacing of the suspenders is not more than 700mm (it is forbidden for the wooden suspenders to directly enter the eye). \ r Self-tapping screws are fixed on the wooden keel. The depth of self-tapping screws entering the wooden keel is not less than 15mm, and the spacing is not more than 250 mm. \r\n H, the sides and bottom surfaces should be covered with gypsum board as far as possible to avoid cracking due to different materials. \r\n 3. Furniture category: \ r \ n a. Cut the veneer according to the design specifications. Note, stick Boeing or Polaroid on the inside. \r\n C Assemble with nails, wood screws or accessories (with glue) according to the design drawings. \r\n D, planing, with nine-lining board or five-lining board on the back and Boeing or Polaroid board on the inside. \ r \ n e. Close the front opening and drawer edge with solid wood. \r\ n N G All-solid wood joinery boards or split-type double-sided saws with a half-spacing of not more than 200mm, double-sided decorative boards, and the gluing time shall not be less than 48h \r\nH. Doors with 25mm thick boards shall be closed on all sides. Doors higher than 1000mm shall be closed with jaws, and the gaps of the doors shall be uniform without deformation \r\nJ. \r\nL, the wood thread is fixed with nail tape \r\nM, and the interior of the furniture cabinet can also be directly painted with mixed oil \r\n4. Wood flooring base: \r\nA. Set horizontal line according to floor thickness \r\nB. Set floor keel line according to floor size (spacing is not more than 300mm) \ r \ n. The depth shall not be less than 50 mm and the spacing shall not be greater than 350 mm. \r\nD, use a dry wooden wedge to expand and nail it into the eye (the wooden wedge is coated with building glue), plane it with a plane above the wall \r\nE, plane it all around (according to the requirements) and fix it with nails or wooden screws, and fix it with building glue. The depth into the wooden wedge shall not be less than 40mm (leveled by four horizontal lines). NG, paved with joinery board or 12cm board, with expansion joint of not less than 6mm at the joint \r\n5. Kitchen cabinet: \ r \ The structural plate of the kitchen cabinet is made of polyurethane board, and the door is made of Weiya fireproof board. Kitchen cabinets and bathroom cabinets must be surrounded by marble or floor tiles or other waterproof materials. Glass glue or special sealant must be used to seal between the countertop of the ground cabinet and the wall surface. Sealing measures should be taken between the washbasin, vegetable sink, embedded cooker and the countertop. \r\n6. Partition wall: \ r \ nFour-sided planed wooden keel (or light steel keel) is used as the frame, with the spacing not more than 400mm, painted with fire retardant paint, and plastered with 9mm thick gypsum board or 5mm thick cement pressure board (plastered with mesh on the surface) \r\n7. Thermal insulation wall: \ r \ nFour-sided planed wooden keel (or light steel keel) is built with rock wool. The joint gap is 300mm or 45 degrees oblique, and the joint is staggered, with the depth less than one third and the joint width less than 300mm\r\n 10. Arrange the vertical pipes in the bathroom and kitchen: \r\nAll sides of the wooden keel shall be planed flat, painted with waterproof paint for 5mm, and the cover of cement pressure plate shall be plastered with iron mesh \ r \ n \ r \ nIf there is lime layer on the original wall surface, it must be removed \r\nB, and the wall surface shall be roughened with 108 glue mud r \r\nC and leveled horizontally. Generally, the brick is repaired to an inconspicuous place \r\n2, and the floor tile (soaked in water for 20 minutes): \r\nA, the floor tile is laid symmetrically \r\nB, the brick is laid from the appearance \r\nC, and the dry and hard paving method (leveling the bottom layer with semi-dry cement mortar first, and laying cement mortar on the back of the floor tile) \r\nD, the wall tile is laid on the floor. Be sure to brush cyanine condensate and asphalt for waterproofing before sticking to the floor in the bathroom and kitchen. The wall is 300mm waterproof from the ground, and the wall with cabinets on the other side of the wall should be waterproof to the top. \r\nF Before laying the floor tiles, the base should be cleaned and watered. Only when there is no obvious water mark on the ground can the surface be pasted \r\nG. The floor of kitchen, bathroom and balcony should be lower than that of room and lobby 1-2 cm \ r \ NH. If there is no special requirement, marble or mirror floor tiles should be used as water baffles between the floor of kitchen and bathroom and the floor of room or lobby. The width is the same as the door cover or other \r\nThird, the painter: \r\n 1, the wall surface is painted with latex paint \r\nA, the original paint surface is removed \r\nB, the back cover is made of 108 glue or alkyd varnish \r\nC, and the insulation board and trunking are used. NE, brush latex paint for two or three times \r\nF, the ceiling and partition must be treated with rust-proof iron \r\n2, the wood surface varnish: \r\nA, the whole polishing, cleaning the stains \r\nB, priming powder, patching holes and seams \r\nC, polishing-cleaning-priming-polishing-oiling with wood as the surface. Hydraulic engineering: \r\n 1. If there are no special design requirements, the water supply pipe shall be made of 15 plastic aluminum pipe, and the hot water pipe shall be made of 15 plastic copper pipe. \r\n2. The distance between water supply pipe and gas pipeline should not be less than 50mm\r\n3. Before the water supply pipeline is rebuilt and concealed, pressure test must be carried out for 20 minutes. Valves should be installed in front of the water inlets of water-using equipment such as water tanks, washbasins, vegetable basins and water heaters, and valves should be installed in the water outlets of water heaters \r\n5. Hot and cold water connections such as washbasin and vegetable basin should be installed below, with left hot and right cold \r\n6. The drain of the bathtub should be aligned with the water outlet, and a manhole should be left (4-6 spare tiles should be reserved). The following requirements must be met: washbasin 32-\r\ n50, vegetable washing pool 40-50 \ r \ n8. If it is not specified in the manual, the toilet should not be fixed with expansion bolts, and the base should be fixed with cement \r\n9. Take protective measures for the installed sanitary ware \r\n 10, and the waterway reconstruction is over. N 1, the circuit is laid with PVC conduit, and the wall groove must be made with cutting machine. Thread in the pipe \r\BV 1.5, socket BV2.5, air conditioner BV4. BV4 should be used when the bathroom is equipped with both bathroom yuba and electric water heater \ r \ nOtherwise, BV2.5 should be used. The location where the downlight is installed must be connected with a cable box. After the circuit is reformed, the insulation resistance of each relative zero, relative ground and ground to zero shall be tested respectively, and the insulation resistance value shall not be less than 0.5M ohm.. If multiple lines are laid in the same pipeline, insulation tests must be conducted between wires in the same pipeline. After insulation tests, all power points (lamps and sockets) should be tested. Finally, the leakage protector test \r\n4 is conducted at the farthest point of each circuit. If there are no special circumstances, the wires must be buried through the tube, and the total cross-sectional area of the power cord in the tube shall not exceed 40% of the inner diameter of the tube. Strong current and weak current shall not be laid in the same pipe or enter the same junction box. \ r \ nThe guide wire in the tube cannot be jointed or twisted. The lead box has allowance, and its length should be 150mm\r\n5. Protective measures should be taken when electrical pipelines pass through doors and other parts that often move during construction. \r\n6. The distance between electric lines and steam hot water pipes should be greater than 500mm, and the distance between electric lines and other pipes should be greater than 100mm\r\n7. Electrical pipes should not be bent at right angles. Unless otherwise specified, the switch sockets in the same room shall be installed at the same elevation, and the top elevation of rows of switch sockets in the same place shall be the same \r\n9. High-power electrical appliances cannot be directly installed on combustible components. \r\n 10。 After the circuit transformation is completed, draw the circuit sketch and provide the circuit diagram to the owner before acceptance.